內容

第四代陶瓷於2003年問世,是現今最廣為使用的人工髖關節摩擴介面材質1,陶瓷頭可以避免發生金屬頭腐蝕和鈷離子引起的病變2,3 ,陶瓷對陶瓷(Coe)的耐磨度更是毋庸置疑4,只不過仍有美中不足之處5
2007年推出的維他命E襯墊,經歷多年臨床考驗,已被證明是搭配陶瓷頭的最佳夥伴,陶瓷對維他命E (CoE)的長期耐磨表現不但和CoC平起平坐,」無碎裂與異音問題,而且能用更大的頭提升穩定度,因此在美國已取代CoC• 成為各方面兼顧的新陶瓷組合,特別在以下這些情況時,CoE通常能比Coe獲得更佳的術後效果:
Reference:
1.Heckmann N, Ihn H, Stefl M, Etkin CD, Springer BD, Berry DJ, Lieberman JR. Early Results From the American Joint Replacement Registry: A Comparison With Other National Registries. J Arthroplasty. 2019 Jan 5. pii: S0883-5403(18)31228-2.
2.Sultan AA, Cantrell WA, Khlopas A, Berger RJ, Sodhi N, Molloy RM, Krebs VE, Mont MA. Evidence-Based Management of Trunnionosis in Metal-on-Polyethylene Total Hip Arthroplasty: A Systematic Review. J Arthroplasty. 2018 Oct;33(10):3343-3353.
3.Pourzal R, Lundberg HJ, Hall DJ, Jacobs JJ. What Factors Drive Taper Corrosion? J Arthroplasty. 2018 Sep;33(9):2707-2711.
4.Solarino G, Piazzolla A, Moretti L, Vicenti G, Moretti B. A minimum 20-year outcome of 100 consecutive alumina-on-alumina arthroplasties performed by a single surgeon. Hip Int. 2018 Nov;28(2_suppl):10-14.
5.Hernigou P, Roubineau F, Bouthors C, Flouzat-Lachaniette CH. What every surgeon should know about Ceramic-on-Ceramic bearings in young patients. EFORT Open Rev. 2017 Mar 13;1(4):107-111.
6.Howard DP, Wall PDH, Fernandez MA, Parsons H, Howard PW. Ceramic-on-ceramic bearing fractures in total hip arthroplasty: an analysis of data from the National Joint Registry. Bone Joint J. 2017 Aug;99-B(8):1012-1019.
7.Lee YK, Ha YC, Yoo JI, Jo WL, Kim KC, Koo KH. Mid-term results of the BIOLOX delta ceramic-on-ceramic total hip arthroplasty. Bone Joint J. 2017 Jun;99-B(6):741-748.
8.Yoon BH, Park IK. Atraumatic Fracture of the BIOLOX delta Ceramic Liner in Well-Fixed Total Hip Implants. Orthopedics. 2018 Nov 1;41(6):e880-e883.
9.Salo PP, Honkanen PB, Ivanova I, Reito A, Pajamäki J, Eskelinen A. High prevalence of noise following Delta ceramic-on-ceramic total hip arthroplasty. Bone Joint J. 2017 Jan;99-B(1):44-50.
10.Blakeney WG, Beaulieu Y, Puliero B, Lavigne M, Roy A, Massé V, Vendittoli PA. Excellent results of large-diameter ceramic-on-ceramic bearings in total hip arthroplasty: Is Squeaking Related to Head Size. Bone Joint J. 2018 Nov;100-B(11):1434-1441.
11.Barrow JA, Divecha HM, Panchani S, Boden R, Chitre A, Gambhir A, Porter ML, Board TN. Is patient satisfaction related to patient reported sounds from ceramic on ceramic total hip arthroplasty? A study of 265 hips. Eur J Orthop Surg Traumatol. 2019 Mar 30.
12.Zhao CC, Qu GX, Yan SG, Cai XZ. Squeaking in fourth-generation ceramic-on-ceramic total hip replacement and the relationship with prosthesis brands: meta-analysis and systematic review. J Orthop Surg Res. 2018 Jun 1;13(1):133.